Solid waste


Laboratory experiments generate solid waste in addition to liquid waste. This solid waste is comprised of all single-use or broken material. Two major criteria will determine the way in which solid waste is sorted and disposed of in a laboratory:

  • Is the solid pointed or sharp?
  • Has the solid been soiled by chemicals (organic solvents, acids, toxic chemicals, etc.)?

Based on the answers to these two questions, you will be able to decide on the right bucket for disposal of the solid waste. Most of the buckets available for laboratory waste are for soiled solids and can collect soiled or unsoiled solids as required.

Decision tree for disposing of your solid waste
Never store a chemical for a long time in unsuitable storage areas (cupboard, under the bench)!

POINTED AND/OR SHARP SOILED WASTE

Photo of a closed plastic seal labeled CMR (paper + glass)
What I must put into the container:
Soiled glass waste (Pasteur pipettes, broken glass)
Pointed and sharp plastic waste (pipette tips)

What I can put into the container:
Unsoiled sharp and/or pointed glass waste
Unsoiled sharp and/or pointed plastic waste (pipette tips)

What I must not put into the container:
Liquid waste or solid waste containing liquid

SOILED WASTE THAT IS NEITHER POINTED NOR SHARP

Photo of a closed plastic seal with handwritten CMR (paper + glass)
What I must put into the container:
Soiled gloves
Soiled paper waste (paper towels)
Soiled plastic waste that is neither pointed nor sharp (test tubes)

What I must not put into the container:
Soiled glass waste (Pasteur pipettes, broken glass)
Pointed and sharp soiled plastic waste (pipette tips)
Liquid waste or solid waste containing liquid
Gloves

UNSOILED LABORATORY WASTE

Picture of a cardboard garbage can containing a plastic bag, labeled with hazard pictograms
What I must put into the container:
Unsoiled gloves
Unsoiled paper towels

What I can put into the container:
Unsoiled laboratory waste that is neither pointed nor sharp
Unsoiled plastic or glass waste (depending on the bin)

What I must not put into the container:
Soiled glass waste (Pasteur pipettes, broken glass)
Liquid waste or solid waste containing liquid
Waste not from the laboratory

CHROMATOGRAPHY VIALS

Picture of a plastic container with the handwritten words "VIALS GLASS + CMR".
What I must put into the container:
Unemptied but closed chromatography vials

What I must not put into the container:
All other solid waste

OTHER UNSOILED WASTE

Picture of a garbage can on the ground containing a blue plastic bag
What I must put into the container:
Waste that is not from the laboratory (school supplies, chewing-gum, empty water bottles, etc.)

What I can put into the container:
Unsoiled waste that is neither pointed nor sharp

What I must not put into the container:
All soiled waste
All pointed or sharp waste

As with liquid waste, the solid waste buckets should be left open for the shortest time possible to reduce exposure to hazardous substances. To this end, these instructions should be followed:

  • Ensure that at least 2 benchtop bins are to hand to collect waste during experiments.1) Pointed and sharp soiled waste and 2) Other soiled waste;
  • Do not Empty the benchtop bins until they are full or until the end of the session;
  • Wherever possible, only open buckets under fume hoods to avoid inhaling residual vapors.
Photo of a beaker on a bench containing used pipettes
Next page