Analysis of a spring water
Determination of NO2- ions using spectrophotometry
Equipment and reagents
- Standard laboratory equipment, in particular: volumetric flasks, spectro cuvettes, Erlenmeyer flasks
- A spectrophotometer
- Orthophosphoric acid solution (H3PO4) at 1.5 mol.L-1
- Diazotization reagent*
- Nitrite aqueous solution at 100 mg.L-1 (stock solution)
- Nitrite calibration solution at 1 mg.L-1
100 mL of orthophosphoric acid
2 g of dichloride of N-(naphtyl-1) diamino-1,2 ethane
40 g of amino-4 benzenesulfonamide
Ultrapure water to make up to 1 L